Sitemap
Principles    Products    Facts    News & Jobs    Press    Contact    Downloads    Home





Seite Drucken
General Data.



Power supply: 24V DC ± 20%, 1A
Maximum operating temperatures: Unit: 55 C, Inductive sensors: 100 C
Self monitoring system unit with watchdog function and system failure alarm
Solid design for operation under rough conditions
Measurement is not influenced by axial or radial movements
The system unit is designed to be integrated in an engine console desk
Fitting dimension: 192 x 147 mm
Potential free relay contacts for alarm output
Analog output for remote indication
Serial port RS232 for measurement and programming
Electrical and environmental testing according to IACS E-10 rules and type approval from DNV